The HP-VSM100 MINI Vital Signs Monitor is designed for monitor blood oxygen saturation,blood pressure and pulse rate which are key parameters for human.It can be used in clinic,ward,hospital ICU,etc.And it can be wall-mounting,trolley style too!Main Featu
χ
This item has added to inquiry basket

Please check your inquiry basket.

χ
This item was already in your inquiry basket

Please check your inquiry basket.

  • Product Detail
  • Send Inquiry

The HP-VSM100 MINI Vital Signs Monitor is designed for monitor blood oxygen saturation,blood pressure and pulse rate which are key parameters for human.It can be used in clinic,ward,hospital ICU,etc.And it can be wall-mounting,trolley style too!

Main Features:
 Built-in memory, store up to 100 hours of patient SpO2 and 500 groups of patient NIBP
 Perfusion Index (PI) measurement as blood perfusion indicator
 High brightness cold cathode fluorescent backlight LCD +LED display
 Advanced analog processing technology providing accurate measurement during low perfusion and movement situation
 Adjustable audible and visual alarms
 Built-in large capacity rechargeable lithium battery
 5V DC power supply for ambulance use


Performance Specifications

Dimension and Weight
 -Dimension: 210mm*170mm*75mm
 -Weight: 1kg(excluding accessories)
 Power Supply
 -Voltage: AC100~240V, 50/60HZ
 -Adapter: Output 5VDC, 4A
 
Display

 -LED + LCD
 -LCD Size: 85mm * 30mm
 
Battery 

 -Type: Rechargeable lithium battery 3.7V/2200mAh
 -Charge Cycle: ≥500 times
 -Working time: 3 hours
 -Optional large battery for 8-9 hours work
 Alarm
 -Level: Low, medium and high
 -Indication: Auditory and visual
 -Alarm volume adjustable
 System Output
 -Ethernet Network: standard RJ45 socket * 1
 -USB Port * 1
 Trend & Reviewing
 -Trend: 100 hours of patient SpO2
 -NIBP measurement reviewing: 500 groups
 Safety
 -IEC60601-1 Approved, CE marking according to MDD93/42/EEC
 -With reference to RoHS Directive 2011/65/EU recasting
 Operating Environment
 -Temperature:  5 ~ 40 ℃
 -Humidity:  15% ~ 80% (non-condensing)
 -Atmosphere pressure:  86 KPa ~ 110 KPa

Transportation and Storage Environment

 -Temperature:  -20~50 ℃
 -Humidity: 10%~90%  (non-condensing)
 -Atmosphere pressure:  86 KPa ~ 110 KPa
SpO2 

 -Measurement Range: 0 ~ 100 %
 -Resolution: 1 %
 -Support Pitch tone and multi-level volume
 -Accuracy:   80% ~ 100%, ±2 % (adult)
 70% ~ 80%, ±3% (adult)
 0% ~ 69%, unspecified
 -PI range:0.075%-20%.
 Pulse Rate
 -Measuring and Alarm Range: 25~250bpm
 -Accuracy: ±1% or ±1 bpm, whichever is greater
 -Resolution: 1bpm
Nellcor SpO2 (Option)

 -Measurement Range: 0 ~ 100 %
 -Resolution: 1 %
 -Accuracy:   70% ~ 100%, ±2 % (adult)
 70% ~ 100%, ±3 % (Neonate)
 70% ~ 100%, ±2 % (Low Perfusion)
 0% ~ 69%, unspecified
 Pulse Rate
 -Measurement range: 20 ~ 300 bpm
 -Resolution: 1bpm
 -Accuracy: ±3 bpm (20 ~ 250 bpm)
 Unspecified (251~300 bpm)

Masimo SpO2 (Option)

 -Measurement Range: 0 ~ 100 %
 -Resolution: 1 %
 -PI range: 0.025-20%
 -Accuracy:
 70% ~ 100%, ±2 % (adult/ pediatric, non-motion conditions)
 70% ~ 100%, ±3 % (neonate, non-motion conditions)
 70% ~ 100%, ±3 % (motion conditions)
 0% ~ 69% unspecified
 Pulse Rate
 -Measurement range: 25 ~ 240 bpm
 -Resolution: 1bpm
 -Accuracy: ±3 bpm (non-motion condition)
 
NIBP

 -Method: Oscillometric
 -Measure mode: Manual, Auto, STAT
 -Measure Interval in AUTO Mode 1~480 min
 -STAT mode cycle time: Keep 5 minutes, at 5 seconds interval
 -Measure and Alarm Range:
 Adult: SYS:  30 ~ 270 mmHg
 DIA:  10 ~ 220 mmHg
 MEAN:  20 ~ 235 mmHg
 Pediatric: SYS:  40 ~ 235 mmHg
 DIA:  10 ~ 220 mmHg
 MEAN:  20 ~ 225 mmHg
 Neonate:   SYS:  30 ~ 135 mmHg
 DIA:  10 ~ 110 mmHg
 MEAN:  20 ~ 125 mmHg
 -Static pressure accuracy: ±3mmHg
 -Resolution: 1mmHg
 -Accuracy: Maximum Mean error ±5mmHg
 Maximum Standard deviation ≤8mmHg
 -Over pressure Protection: Dual protection via software & hardware
 * Specifications subject to change without prior notice


Model Configuration:

HP-VSM100A:SpO2, Pulse Rate, Perfusion Index

HP-VSM100B:SpO2, Pulse Rate, NIBP, Perfusion Index

Optional

Nellcor SpO2 , Masimo SpO2  

Optional Accessories:

Wall-mounting, Trolley, Neonatal /Pediatric Accessories

Note:1,HEPO supply one year quality guarantee and 24 hours phone service for all the products supplied.2,Installation and training service can be supplied accordingly