prev
  • HP-AA560B4 High End Clinical Anesthesia Machine
next
Prev | Next
SKU: AA560B4
HP-AA560B4 High End Clinical Anesthesia Machine
Description
HP-AA560B4 Anesthesia apparatus with its ergonomic design,integrates a concise and smooth structure and high mobility.The microcomputer-controlled Ventilator adopts exported sensors and other components.
χ
This item has added to inquiry basket

Please check your inquiry basket.

χ
This item was already in your inquiry basket

Please check your inquiry basket.

  • Product Detail
  • Send Inquiry

HP-AA560B4 Anesthesia apparatus with its ergonomic design,integrates a concise and smooth structure and high mobility.The microcomputer-controlled Ventilator adopts exported sensors and other components.Its scientific and proper design as well as rigorous production process are what demonstrate the inner quality of us:mechanical ventilation is made secure and visible by the folded respiratory bellows,and the security of air supply is guaranteed by pneumatic transmission and measurement system.With multiple modern technologies applied,the Anesthesia Machine is both outstanding in performance and versatile in functions.

Main Advantages:
1,The Ventilator adopts microcomputer control with high-definition 5.7” LCD display, integrating the functions of respiratory control and displaying the monitoring parameters. It is versatile in function and excellent in performance.
2,The high-precision Vaporizer is designed with a stable concentration output, automatic compensation for pressure, temperature and flow rate. And it is available to choose two kinds of gas from Halothane, Enflurane, Isoflurane, and Sevoflurane, ensuring a successful anesthesia operation.
3,High-definition four-tube flowmeter, designed with stoppers for oxygen and nitrous oxide to control the output oxygen concentration.
4,Reliable pneumatic transmission system.
5,Economic and proper configuration of technologies, optional as required by the Customer.
6,Modularized design and upgrading. Upgrading is available as required by the Customer.

Composition of Anesthesia
1,Main body: High-strength engineering plastic rack, light, beautiful and corrosion resistant
2,Scope of application:  Adult,child
3,Gas source:  O2: 0.27~0.55MPa    N2O: 0.27~0.55MPa
4,Flow meter:  O2:  0.1~1.0L/min     1.1~10L/min
 N20: 0.1~1.0L/min     1.1~10L/min
5,O2, N2O linkage and N2O Stopper:
When using nitrous oxide, oxygen concentration>25%;
When the oxygen pressure<0.2Kpa, the flow of nitrous oxide would be cut off.
6,Flow rate of rapid oxygen supply:  25~75L/min
7,Low oxygen pressure alarm:  There will be sound alarm when the oxygen pressure < 0.2MPa
8,Vaporizer: It has the function of automatic compensation based on pressure, temperature, and flow rate. The regulation range of evaporator concentration is 0~5 vol%.
Among Halothane,Enflurane,Isoflurane and Sevoflurane,two can be chosen for application as required by the customer. And vaporizers that are imported with original packaging are also available.
9,Respiratory circuit: Working mode: all-close, semi-close, semi-open
   APL: 0.5~7 k
10,Respiratory Bellows:  Bellows for adults, bellows for children
 Tidal volume range:0~1,500 ml
 
Composition of Ventilator
1,Display mode:  High-definition 5.7” LCD screen display
2,Ventilation mode:  IPPV, SIPPV, SIMV, PEEP, MANUAL, SIGH
3,Ventilation parameters: Tidal volume       50~1500 ml
 Rate:              2~99 bpm
 SIMV rate:     2~20 bpm
 I:E                  2:1~1:8
 Inspiratory trigger pressure  -1.0~2.0 kPa
 PEEP:          0~2.0 kPa
 Pressure range: 1.0~6.0 kPa
 SIGH:           1.5 times the inspiratory time
4,Parameters for ventilation monitoring:  Tidal volume, ventilation volume, IPPV rate, SIMV rate, total respiratory rate, I/E, peak pressure of airway, pressure - time waveform, flow rate - time waveform, PEEP, inspiratory trigger pressure
5,Monitoring of oxygen concentration:  (21%~100%)
6,Security Alarm System
 Oxygen Concentration alarm:  Upper limit setting range   (50%~100%)
 Low limit setting range    (15%~50%)
 Airway pressure alarm:   Upper limit setting range   1.0~6.0 kPa
 Low limit setting range    0.4~2.0 kPa
 Per-minute ventilation volume alarm:  Upper limit setting range   3.0~30L/min
 Low limit setting range    1.0~10L/min
 Sustained high-pressure alarm    It will give alarm when stress have consistently been higher than 2.5 kPa
 Suffocation alarm:    It will give sound and light alarm if there is no tidal volume input for 15 seconds
 Power alarm
7, Power:  AC 220V±10%     50Hz±1Hz
 (UPS, Storage battery)
8,(Mechanical Arms)
9,(End-expiratory CO2 monitoring)
10,Package Details:  Plywood Case:770*780*1440mm,N.W./G.W.:56/92kgs
 800*430*380mm,N.W./G.W.:26/37kgs


Note:Items within brackets are optional.


Note:
One year quality guarantee and 24 hours phone service for all the products supplied.