prev
  • Popular Mammography X Ray System
next
Prev | Next
SKU: HP-MAMG500
Popular Mammography X Ray System
Description
Product BriefingHP-MAMG500 High-Frequency Mammographic Unit is an X-ray apparatus involving in various advanced technologies, specially designed for the diagnosis of mammary gland diseases. It is sensitive to mammary gland lump, calcification, protuberanc
χ
This item has added to inquiry basket

Please check your inquiry basket.

χ
This item was already in your inquiry basket

Please check your inquiry basket.

  • Product Detail
  • Send Inquiry

Product Briefing

HP-MAMG500 High-Frequency Mammographic Unit is an X-ray apparatus involving in various advanced technologies, specially designed for the diagnosis of mammary gland diseases. It is sensitive to mammary gland lump, calcification, protuberance and carcinogensis and first-choice apparatus for the image examination of mammary diseases in medical institutes. 

HP-MAMG500 is put into mass production based on the experience of long-term clinical tests in various hospitals after 5 remodification cycles. The adoption of the Toshiba patented rotary anode molybdenum target X-ray tube helps to improve the image definition. Its high-power, distant controlled, high-frequency, high-pressure generator adopted newest IGBT power tube and programmable logic array technology. The frequency, as high as 80kHz, contributes to a more smooth power output with less scattered radiation, improving the picture contrast. The computerized control and operation further improves its safety, reliability, as well as ease of use. The mechanic design borrows some ideas from the popular models global wide and adopts the latest human engineering technologies, which are designed to add comfort to the patient’s examination.

     

X-ray Generator

Generator Type:High Frequency Inverter 40kHz

Input Power: Single phase 220VAC, 50/60Hz

Radiographic Ratings:Large Focal Point 20-35kV/10-510mAs

                     Small Focal Point 20-35kV/10-100mAs

Power Rating:3.6kW


X-ray Tube

Model:IAE C339V

Focal Spot Size: Dual Focus 0.1 / 0.3mm

X ray tube current : 0~120mA

Target Material:Molybdenum (Mo)

Port Material:Beryllium (Be)

Anode Heat Storage: 300kHU

Anode Cooling:Air cooling

Filtration: Mo(0.03mm),Al(0.5mm)


Radiographic Stand 

C-ARM:Vertical Movement:580mm

Rotations Deg:+175°~-180°

SID: 650mm


Cassette Image Receptor 

Bucky Device:18×24cm Bucky drive mechanism

Grid Ratio:5:1 ,30 Line/cm


Line Voltage 

220Vac@25A,Single phase


Weight

240kg