SKU: HP-VL210
Clinic Popular Medical Operation Ventilator
Description
HP-VL210 is a multi-functional Ventilator, it is applicable for children and adults in sickroom, ICU or of emergency. Display                  colored LCD,
χ
This item has added to inquiry basket

Please check your inquiry basket.

χ
This item was already in your inquiry basket

Please check your inquiry basket.

  • Product Detail
  • Send Inquiry

HP-VL21is a multi-functional Ventilator, it is applicable for children and adults in sickroom, ICU or of emergency. 


Display                  colored LCD, touch screen setting, big font display, free changeable angles of views  
 Various ventilation modes       SIPPV、SIMV、PCV、SPONT、MANUAL、CPAP
 Ventilation parameters          PEEP、SIGH、IRV、Inspiratory platform
 Tidal Volume                  50-1500 mL
 Rate                         1~99bpm
 SIMVrate                     2~20bpm
 I:E                          4:1~1:8  
 Trigger sensitivity             -1.0~1.0kPa    
 PEEP                        0~25cmH2O  
 Pressure control               3~50cmH2O  
 SIGH                  1.5 times the inspiratory time (60 ~ 120 times adjustable)      
 Inspiratory platform            0~50%   
 Oxygen concentration          48%~100%   
 Pressure limit                5~60cmH2O  
 Parameters for ventilation monitoring     tidal volume, ventilation volume, IPPV rate, total respiratory rate, peak pressure of airway, pressure - time waveform, flow rate - time waveform, inspiratory trigger pressure, Inspiratory platform, Oxygen concentration, battery capacity
 Safety alarm system    
 Airway pressure alarm                 upper limit setting range   0.3~6.0 kPa
 lower limit setting range    0.2~5.0 kPa
 Per-minute ventilation volume alarm      upper limit setting range 3.0~30L/min  
 lower limit setting range  1.0~10L/min
 Vt alarm                            upper limit setting range 10~2000ml    
 lower limit setting range  0~1800 ml     
 Sustained high-pressure alarm       it will give alarm when stress have consistently been higher than 2.5 kPa                                                   
 Suffocation alarm                 it will give sound and light alarm if there is no tidal volume input for 15 seconds     
 Power failure alar alarm        
                                UPS, Storage battery    
 Battery under-voltage alarm
 Power loss alarm  
 Intubation off alarm     
 Heated humnidifier          s no tidal volume input for 15 seconds
 Power alarm
  AC 220V/50Hz or AC 110V/60Hz is optional
Mechaincal Arms